Copy Grid software on rac1 and unzip it.
BASH[grid@rac1 ~]$ ls -lrth
total 2.7G
-rw-r--r-- 1 grid oinstall 2.7G Sep 27 00:33 grid-19c.zip
[grid@rac1 ~]$ unzip grid-19c.zip -d /u01/app/grid/19.0.0/gridhome_1/
Crosscheck prerequest Cluster Ready Services on both nodes rac1 and rac2
go inside grid and run below command.
BASH[grid@rac1 gridhome_1]$ ./runcluvfy.sh stage -pre crsinst -n rac1,rac2 -fixup -verbose
Verifying Physical Memory ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 5.3685GB (5629256.0KB) 8GB (8388608.0KB) failed
rac1 5.3685GB (5629244.0KB) 8GB (8388608.0KB) failed
Verifying Physical Memory ...FAILED (PRVF-7530)
Verifying Available Physical Memory ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 3.3264GB (3488008.0KB) 50MB (51200.0KB) passed
rac1 2.4GB (2516560.0KB) 50MB (51200.0KB) passed
Verifying Available Physical Memory ...PASSED
Verifying Swap Size ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 3.875GB (4063228.0KB) 5.3685GB (5629256.0KB) failed
rac1 3.875GB (4063228.0KB) 5.3685GB (5629244.0KB) failed
Verifying Swap Size ...FAILED (PRVF-7573)
Verifying Free Space: rac2:/usr,rac2:/var,rac2:/etc,rac2:/u01/app/grid/19.0.0/gridhome_1,rac2:/sbin,rac2:/tmp ...
Path Node Name Mount point Available Required Status
---------------- ------------ ------------ ------------ ------------ ------------
/usr rac2 / 30.8301GB 25MB passed
/var rac2 / 30.8301GB 5MB passed
/etc rac2 / 30.8301GB 25MB passed
/u01/app/grid/19.0.0/gridhome_1 rac2 / 30.8301GB 6.9GB passed
/sbin rac2 / 30.8301GB 10MB passed
/tmp rac2 / 30.8301GB 1GB passed
Verifying Free Space: rac2:/usr,rac2:/var,rac2:/etc,rac2:/u01/app/grid/19.0.0/gridhome_1,rac2:/sbin,rac2:/tmp ...PASSED
Verifying Free Space: rac1:/usr,rac1:/var,rac1:/etc,rac1:/u01/app/grid/19.0.0/gridhome_1,rac1:/sbin,rac1:/tmp ...
Path Node Name Mount point Available Required Status
---------------- ------------ ------------ ------------ ------------ ------------
/usr rac1 / 30.5645GB 25MB passed
/var rac1 / 30.5645GB 5MB passed
/etc rac1 / 30.5645GB 25MB passed
/u01/app/grid/19.0.0/gridhome_1 rac1 / 30.5645GB 6.9GB passed
/sbin rac1 / 30.5645GB 10MB passed
/tmp rac1 / 30.5645GB 1GB passed
Verifying Free Space: rac1:/usr,rac1:/var,rac1:/etc,rac1:/u01/app/grid/19.0.0/gridhome_1,rac1:/sbin,rac1:/tmp ...PASSED
Verifying User Existence: grid ...
Node Name Status Comment
------------ ------------------------ ------------------------
rac2 passed exists(54323)
rac1 passed exists(54323)
Verifying Users With Same UID: 54323 ...PASSED
Verifying User Existence: grid ...PASSED
Verifying Group Existence: asmadmin ...
Node Name Status Comment
------------ ------------------------ ------------------------
rac2 passed exists
rac1 passed exists
Verifying Group Existence: asmadmin ...PASSED
Verifying Group Existence: asmdba ...
Node Name Status Comment
------------ ------------------------ ------------------------
rac2 passed exists
rac1 passed exists
Verifying Group Existence: asmdba ...PASSED
Verifying Group Existence: oinstall ...
Node Name Status Comment
------------ ------------------------ ------------------------
rac2 passed exists
rac1 passed exists
Verifying Group Existence: oinstall ...PASSED
Verifying Group Membership: asmdba ...
Node Name User Exists Group Exists User in Group Status
---------------- ------------ ------------ ------------ ----------------
rac2 yes yes yes passed
rac1 yes yes yes passed
Verifying Group Membership: asmdba ...PASSED
Verifying Group Membership: asmadmin ...
Node Name User Exists Group Exists User in Group Status
---------------- ------------ ------------ ------------ ----------------
rac2 yes yes yes passed
rac1 yes yes yes passed
Verifying Group Membership: asmadmin ...PASSED
Verifying Group Membership: oinstall(Primary) ...
Node Name User Exists Group Exists User in Group Primary Status
---------------- ------------ ------------ ------------ ------------ ------------
rac2 yes yes yes yes passed
rac1 yes yes yes yes passed
Verifying Group Membership: oinstall(Primary) ...PASSED
Verifying Run Level ...
Node Name run level Required Status
------------ ------------------------ ------------------------ ----------
rac2 5 3,5 passed
rac1 5 3,5 passed
Verifying Run Level ...PASSED
Verifying Hard Limit: maximum open file descriptors ...
Node Name Type Available Required Status
---------------- ------------ ------------ ------------ ----------------
rac2 hard 65536 65536 passed
rac1 hard 65536 65536 passed
Verifying Hard Limit: maximum open file descriptors ...PASSED
Verifying Soft Limit: maximum open file descriptors ...
Node Name Type Available Required Status
---------------- ------------ ------------ ------------ ----------------
rac2 soft 1024 1024 passed
rac1 soft 1024 1024 passed
Verifying Soft Limit: maximum open file descriptors ...PASSED
Verifying Hard Limit: maximum user processes ...
Node Name Type Available Required Status
---------------- ------------ ------------ ------------ ----------------
rac2 hard 16384 16384 passed
rac1 hard 16384 16384 passed
Verifying Hard Limit: maximum user processes ...PASSED
Verifying Soft Limit: maximum user processes ...
Node Name Type Available Required Status
---------------- ------------ ------------ ------------ ----------------
rac2 soft 16384 2047 passed
rac1 soft 16384 2047 passed
Verifying Soft Limit: maximum user processes ...PASSED
Verifying Soft Limit: maximum stack size ...
Node Name Type Available Required Status
---------------- ------------ ------------ ------------ ----------------
rac2 soft 10240 10240 passed
rac1 soft 10240 10240 passed
Verifying Soft Limit: maximum stack size ...PASSED
Verifying Architecture ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 x86_64 x86_64 passed
rac1 x86_64 x86_64 passed
Verifying Architecture ...PASSED
Verifying OS Kernel Version ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 5.4.17-2136.335.4.el7uek.x86_64 4.1.12 passed
rac1 5.4.17-2136.335.4.el7uek.x86_64 4.1.12 passed
Verifying OS Kernel Version ...PASSED
Verifying OS Kernel Parameter: semmsl ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 250 250 250 passed
rac2 250 250 250 passed
Verifying OS Kernel Parameter: semmsl ...PASSED
Verifying OS Kernel Parameter: semmns ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 32000 32000 32000 passed
rac2 32000 32000 32000 passed
Verifying OS Kernel Parameter: semmns ...PASSED
Verifying OS Kernel Parameter: semopm ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 100 100 100 passed
rac2 100 100 100 passed
Verifying OS Kernel Parameter: semopm ...PASSED
Verifying OS Kernel Parameter: semmni ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 128 128 128 passed
rac2 128 128 128 passed
Verifying OS Kernel Parameter: semmni ...PASSED
Verifying OS Kernel Parameter: shmmax ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 4398046511104 4398046511104 2882172928 passed
rac2 4398046511104 4398046511104 2882179072 passed
Verifying OS Kernel Parameter: shmmax ...PASSED
Verifying OS Kernel Parameter: shmmni ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 4096 4096 4096 passed
rac2 4096 4096 4096 passed
Verifying OS Kernel Parameter: shmmni ...PASSED
Verifying OS Kernel Parameter: shmall ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 1073741824 1073741824 1073741824 passed
rac2 1073741824 1073741824 1073741824 passed
Verifying OS Kernel Parameter: shmall ...PASSED
Verifying OS Kernel Parameter: file-max ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 6815744 6815744 6815744 passed
rac2 6815744 6815744 6815744 passed
Verifying OS Kernel Parameter: file-max ...PASSED
Verifying OS Kernel Parameter: ip_local_port_range ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 between 9000 & 65500 between 9000 & 65500 between 9000 & 65535 passed
rac2 between 9000 & 65500 between 9000 & 65500 between 9000 & 65535 passed
Verifying OS Kernel Parameter: ip_local_port_range ...PASSED
Verifying OS Kernel Parameter: rmem_default ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 262144 262144 262144 passed
rac2 262144 262144 262144 passed
Verifying OS Kernel Parameter: rmem_default ...PASSED
Verifying OS Kernel Parameter: rmem_max ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 4194304 4194304 4194304 passed
rac2 4194304 4194304 4194304 passed
Verifying OS Kernel Parameter: rmem_max ...PASSED
Verifying OS Kernel Parameter: wmem_default ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 262144 262144 262144 passed
rac2 262144 262144 262144 passed
Verifying OS Kernel Parameter: wmem_default ...PASSED
Verifying OS Kernel Parameter: wmem_max ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 1048576 1048576 1048576 passed
rac2 1048576 1048576 1048576 passed
Verifying OS Kernel Parameter: wmem_max ...PASSED
Verifying OS Kernel Parameter: aio-max-nr ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 1048576 1048576 1048576 passed
rac2 1048576 1048576 1048576 passed
Verifying OS Kernel Parameter: aio-max-nr ...PASSED
Verifying OS Kernel Parameter: panic_on_oops ...
Node Name Current Configured Required Status Comment
---------------- ------------ ------------ ------------ ------------ ------------
rac1 1 1 1 passed
rac2 1 1 1 passed
Verifying OS Kernel Parameter: panic_on_oops ...PASSED
Verifying Package: kmod-20-21 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 kmod(x86_64)-20-28.0.3.el7 kmod(x86_64)-20-21 passed
rac1 kmod(x86_64)-20-28.0.3.el7 kmod(x86_64)-20-21 passed
Verifying Package: kmod-20-21 (x86_64) ...PASSED
Verifying Package: kmod-libs-20-21 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 kmod-libs(x86_64)-20-28.0.3.el7 kmod-libs(x86_64)-20-21 passed
rac1 kmod-libs(x86_64)-20-28.0.3.el7 kmod-libs(x86_64)-20-21 passed
Verifying Package: kmod-libs-20-21 (x86_64) ...PASSED
Verifying Package: binutils-2.23.52.0.1 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 binutils-2.27-44.base.0.3.el7_9.1 binutils-2.23.52.0.1 passed
rac1 binutils-2.27-44.base.0.3.el7_9.1 binutils-2.23.52.0.1 passed
Verifying Package: binutils-2.23.52.0.1 ...PASSED
Verifying Package: compat-libcap1-1.10 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 compat-libcap1-1.10-7.el7 compat-libcap1-1.10 passed
rac1 compat-libcap1-1.10-7.el7 compat-libcap1-1.10 passed
Verifying Package: compat-libcap1-1.10 ...PASSED
Verifying Package: libgcc-4.8.2 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 libgcc(x86_64)-4.8.5-44.0.3.el7 libgcc(x86_64)-4.8.2 passed
rac1 libgcc(x86_64)-4.8.5-44.0.3.el7 libgcc(x86_64)-4.8.2 passed
Verifying Package: libgcc-4.8.2 (x86_64) ...PASSED
Verifying Package: libstdc++-4.8.2 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 libstdc++(x86_64)-4.8.5-44.0.3.el7 libstdc++(x86_64)-4.8.2 passed
rac1 libstdc++(x86_64)-4.8.5-44.0.3.el7 libstdc++(x86_64)-4.8.2 passed
Verifying Package: libstdc++-4.8.2 (x86_64) ...PASSED
Verifying Package: libstdc++-devel-4.8.2 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 libstdc++-devel(x86_64)-4.8.5-44.0.3.el7 libstdc++-devel(x86_64)-4.8.2 passed
rac1 libstdc++-devel(x86_64)-4.8.5-44.0.3.el7 libstdc++-devel(x86_64)-4.8.2 passed
Verifying Package: libstdc++-devel-4.8.2 (x86_64) ...PASSED
Verifying Package: sysstat-10.1.5 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 sysstat-10.1.5-20.0.3.el7_9 sysstat-10.1.5 passed
rac1 sysstat-10.1.5-20.0.3.el7_9 sysstat-10.1.5 passed
Verifying Package: sysstat-10.1.5 ...PASSED
Verifying Package: ksh ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 ksh ksh passed
rac1 ksh ksh passed
Verifying Package: ksh ...PASSED
Verifying Package: make-3.82 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 make-3.82-24.el7 make-3.82 passed
rac1 make-3.82-24.el7 make-3.82 passed
Verifying Package: make-3.82 ...PASSED
Verifying Package: glibc-2.17 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 glibc(x86_64)-2.17-326.0.9.el7_9.3 glibc(x86_64)-2.17 passed
rac1 glibc(x86_64)-2.17-326.0.9.el7_9.3 glibc(x86_64)-2.17 passed
Verifying Package: glibc-2.17 (x86_64) ...PASSED
Verifying Package: glibc-devel-2.17 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 glibc-devel(x86_64)-2.17-326.0.9.el7_9.3 glibc-devel(x86_64)-2.17 passed
rac1 glibc-devel(x86_64)-2.17-326.0.9.el7_9.3 glibc-devel(x86_64)-2.17 passed
Verifying Package: glibc-devel-2.17 (x86_64) ...PASSED
Verifying Package: libaio-0.3.109 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 libaio(x86_64)-0.3.109-13.el7 libaio(x86_64)-0.3.109 passed
rac1 libaio(x86_64)-0.3.109-13.el7 libaio(x86_64)-0.3.109 passed
Verifying Package: libaio-0.3.109 (x86_64) ...PASSED
Verifying Package: libaio-devel-0.3.109 (x86_64) ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 libaio-devel(x86_64)-0.3.109-13.el7 libaio-devel(x86_64)-0.3.109 passed
rac1 libaio-devel(x86_64)-0.3.109-13.el7 libaio-devel(x86_64)-0.3.109 passed
Verifying Package: libaio-devel-0.3.109 (x86_64) ...PASSED
Verifying Package: nfs-utils-1.2.3-15 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 nfs-utils-1.3.0-0.68.0.1.el7.2 nfs-utils-1.2.3-15 passed
rac1 nfs-utils-1.3.0-0.68.0.1.el7.2 nfs-utils-1.2.3-15 passed
Verifying Package: nfs-utils-1.2.3-15 ...PASSED
Verifying Package: smartmontools-6.2-4 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 smartmontools-7.0-2.el7 smartmontools-6.2-4 passed
rac1 smartmontools-7.0-2.el7 smartmontools-6.2-4 passed
Verifying Package: smartmontools-6.2-4 ...PASSED
Verifying Package: net-tools-2.0-0.17 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 net-tools-2.0-0.25.20131004git.el7 net-tools-2.0-0.17 passed
rac1 net-tools-2.0-0.25.20131004git.el7 net-tools-2.0-0.17 passed
Verifying Package: net-tools-2.0-0.17 ...PASSED
Verifying Users With Same UID: 0 ...PASSED
Verifying Current Group ID ...PASSED
Verifying Root user consistency ...
Node Name Status
------------------------------------ ------------------------
rac2 passed
rac1 passed
Verifying Root user consistency ...PASSED
Verifying Package: cvuqdisk-1.0.10-1 ...
Node Name Available Required Status
------------ ------------------------ ------------------------ ----------
rac2 cvuqdisk-1.0.10-1 cvuqdisk-1.0.10-1 passed
rac1 cvuqdisk-1.0.10-1 cvuqdisk-1.0.10-1 passed
Verifying Package: cvuqdisk-1.0.10-1 ...PASSED
Verifying Host name ...PASSED
Verifying Node Connectivity ...
Verifying Hosts File ...
Node Name Status
------------------------------------ ------------------------
rac1 passed
rac2 passed
Verifying Hosts File ...PASSED
Interface information for node "rac1"
Name IP Address Subnet Gateway Def. Gateway HW Address MTU
------ --------------- --------------- --------------- --------------- ----------------- ------
enp0s3 192.168.29.25 192.168.29.0 0.0.0.0 192.168.29.1 08:00:27:C1:6F:28 1500
enp0s3 192.168.29.93 192.168.29.0 0.0.0.0 192.168.29.1 08:00:27:C1:6F:28 1500
enp0s3 192.168.29.92 192.168.29.0 0.0.0.0 192.168.29.1 08:00:27:C1:6F:28 1500
enp0s3 192.168.29.71 192.168.29.0 0.0.0.0 192.168.29.1 08:00:27:C1:6F:28 1500
enp0s9 192.168.10.1 192.168.10.0 0.0.0.0 192.168.29.1 08:00:27:E2:A9:C2 1500
Interface information for node "rac2"
Name IP Address Subnet Gateway Def. Gateway HW Address MTU
------ --------------- --------------- --------------- --------------- ----------------- ------
enp0s3 192.168.29.217 192.168.29.0 0.0.0.0 192.168.29.1 08:00:27:83:D6:96 1500
enp0s3 192.168.29.72 192.168.29.0 0.0.0.0 192.168.29.1 08:00:27:83:D6:96 1500
enp0s3 192.168.29.91 192.168.29.0 0.0.0.0 192.168.29.1 08:00:27:83:D6:96 1500
enp0s9 192.168.10.2 192.168.10.0 0.0.0.0 192.168.29.1 08:00:27:CD:4C:CA 1500
Check: MTU consistency on the private interfaces of subnet "192.168.10.0"
Node Name IP Address Subnet MTU
---------------- ------------ ------------ ------------ ----------------
rac1 enp0s9 192.168.10.1 192.168.10.0 1500
rac2 enp0s9 192.168.10.2 192.168.10.0 1500
Check: MTU consistency of the subnet "192.168.29.0".
Node Name IP Address Subnet MTU
---------------- ------------ ------------ ------------ ----------------
rac1 enp0s3 192.168.29.25 192.168.29.0 1500
rac1 enp0s3 192.168.29.93 192.168.29.0 1500
rac1 enp0s3 192.168.29.92 192.168.29.0 1500
rac1 enp0s3 192.168.29.71 192.168.29.0 1500
rac2 enp0s3 192.168.29.217 192.168.29.0 1500
rac2 enp0s3 192.168.29.72 192.168.29.0 1500
rac2 enp0s3 192.168.29.91 192.168.29.0 1500
Source Destination Connected?
------------------------------ ------------------------------ ----------------
rac1[enp0s3:192.168.29.25] rac1[enp0s3:192.168.29.93] yes
rac1[enp0s3:192.168.29.25] rac1[enp0s3:192.168.29.92] yes
rac1[enp0s3:192.168.29.25] rac1[enp0s3:192.168.29.71] yes
rac1[enp0s3:192.168.29.25] rac2[enp0s3:192.168.29.217] yes
rac1[enp0s3:192.168.29.25] rac2[enp0s3:192.168.29.72] yes
rac1[enp0s3:192.168.29.25] rac2[enp0s3:192.168.29.91] yes
rac1[enp0s3:192.168.29.93] rac1[enp0s3:192.168.29.92] yes
rac1[enp0s3:192.168.29.93] rac1[enp0s3:192.168.29.71] yes
rac1[enp0s3:192.168.29.93] rac2[enp0s3:192.168.29.217] yes
rac1[enp0s3:192.168.29.93] rac2[enp0s3:192.168.29.72] yes
rac1[enp0s3:192.168.29.93] rac2[enp0s3:192.168.29.91] yes
rac1[enp0s3:192.168.29.92] rac1[enp0s3:192.168.29.71] yes
rac1[enp0s3:192.168.29.92] rac2[enp0s3:192.168.29.217] yes
rac1[enp0s3:192.168.29.92] rac2[enp0s3:192.168.29.72] yes
rac1[enp0s3:192.168.29.92] rac2[enp0s3:192.168.29.91] yes
rac1[enp0s3:192.168.29.71] rac2[enp0s3:192.168.29.217] yes
rac1[enp0s3:192.168.29.71] rac2[enp0s3:192.168.29.72] yes
rac1[enp0s3:192.168.29.71] rac2[enp0s3:192.168.29.91] yes
rac2[enp0s3:192.168.29.217] rac2[enp0s3:192.168.29.72] yes
rac2[enp0s3:192.168.29.217] rac2[enp0s3:192.168.29.91] yes
rac2[enp0s3:192.168.29.72] rac2[enp0s3:192.168.29.91] yes
Source Destination Connected?
------------------------------ ------------------------------ ----------------
rac1[enp0s9:192.168.10.1] rac2[enp0s9:192.168.10.2] yes
Verifying Check that maximum (MTU) size packet goes through subnet ...PASSED
Verifying subnet mask consistency for subnet "192.168.29.0" ...PASSED
Verifying subnet mask consistency for subnet "192.168.10.0" ...PASSED
Verifying Node Connectivity ...PASSED
Verifying Multicast or broadcast check ...
Checking subnet "192.168.10.0" for multicast communication with multicast group "224.0.0.251"
Verifying Multicast or broadcast check ...PASSED
Verifying ASMLib installation and configuration verification. ...
Verifying '/etc/init.d/oracleasm' ...PASSED
Verifying '/dev/oracleasm' ...PASSED
Verifying '/etc/sysconfig/oracleasm' ...PASSED
Node Name Status
------------------------------------ ------------------------
rac1 passed
rac2 passed
Verifying ASMLib installation and configuration verification. ...PASSED
Verifying ASM Integrity ...PASSED
Verifying Network Time Protocol (NTP) ...
Verifying '/etc/chrony.conf' ...
Node Name File exists?
------------------------------------ ------------------------
rac2 yes
rac1 yes
Verifying '/etc/chrony.conf' ...PASSED
Verifying Daemon 'chronyd' ...
Node Name Running?
------------------------------------ ------------------------
rac2 yes
rac1 yes
Verifying Daemon 'chronyd' ...PASSED
Verifying NTP daemon or service using UDP port 123 ...
Node Name Port Open?
------------------------------------ ------------------------
rac2 yes
rac1 yes
Verifying NTP daemon or service using UDP port 123 ...PASSED
Verifying chrony daemon is synchronized with at least one external time source ...PASSED
Verifying Network Time Protocol (NTP) ...PASSED
Verifying Same core file name pattern ...PASSED
Verifying User Mask ...
Node Name Available Required Comment
------------ ------------------------ ------------------------ ----------
rac2 0022 0022 passed
rac1 0022 0022 passed
Verifying User Mask ...PASSED
Verifying User Not In Group "root": grid ...
Node Name Status Comment
------------ ------------------------ ------------------------
rac2 passed does not exist
rac1 passed does not exist
Verifying User Not In Group "root": grid ...PASSED
Verifying Time zone consistency ...PASSED
Verifying Time offset between nodes ...PASSED
Verifying resolv.conf Integrity ...
Node Name Status
------------------------------------ ------------------------
rac1 passed
rac2 passed
checking response for name "rac1" from each of the name servers specified in
"/etc/resolv.conf"
Node Name Source Comment Status
------------ ------------------------ ------------------------ ----------
rac1 192.168.29.1 IPv4 failed
rac1 2405:201:e005:2105::c0a8:1d01 IPv4 failed
checking response for name "rac2" from each of the name servers specified in
"/etc/resolv.conf"
Node Name Source Comment Status
------------ ------------------------ ------------------------ ----------
rac2 192.168.29.1 IPv4 failed
rac2 2405:201:e005:2105::c0a8:1d01 IPv4 failed
checking response for name "rac2" from each of the name servers specified in
"/etc/resolv.conf"
Node Name Source Comment Status
------------ ------------------------ ------------------------ ----------
rac2 192.168.29.1 IPv6 failed
rac2 2405:201:e005:2105::c0a8:1d01 IPv6 failed
checking response for name "rac1" from each of the name servers specified in
"/etc/resolv.conf"
Node Name Source Comment Status
------------ ------------------------ ------------------------ ----------
rac1 192.168.29.1 IPv6 failed
rac1 2405:201:e005:2105::c0a8:1d01 IPv6 failed
Verifying resolv.conf Integrity ...FAILED (PRVG-2048, PRVG-10048)
Verifying DNS/NIS name service ...PASSED
Verifying Domain Sockets ...FAILED (PRVG-11750)
Verifying /boot mount ...PASSED
Verifying Daemon "avahi-daemon" not configured and running ...
Node Name Configured Status
------------ ------------------------ ------------------------
rac2 no passed
rac1 no passed
Node Name Running? Status
------------ ------------------------ ------------------------
rac2 no passed
rac1 no passed
Verifying Daemon "avahi-daemon" not configured and running ...PASSED
Verifying Daemon "proxyt" not configured and running ...
Node Name Configured Status
------------ ------------------------ ------------------------
rac2 no passed
rac1 no passed
Node Name Running? Status
------------ ------------------------ ------------------------
rac2 no passed
rac1 no passed
Verifying Daemon "proxyt" not configured and running ...PASSED
Verifying loopback network interface address ...PASSED
Verifying Grid Infrastructure home path: /u01/app/grid/19.0.0/gridhome_1 ...
Verifying '/u01/app/grid/19.0.0/gridhome_1' ...FAILED (PRVG-11931)
Verifying Grid Infrastructure home path: /u01/app/grid/19.0.0/gridhome_1 ...FAILED (PRVG-11931)
Verifying User Equivalence ...PASSED
Verifying RPM Package Manager database ...INFORMATION (PRVG-11250)
Verifying Network interface bonding status of private interconnect network interfaces ...PASSED
Verifying /dev/shm mounted as temporary file system ...PASSED
Verifying File system mount options for path /var ...PASSED
Verifying DefaultTasksMax parameter ...PASSED
Verifying zeroconf check ...PASSED
Verifying ASM Filter Driver configuration ...PASSED
Verifying Systemd login manager IPC parameter ...PASSED
Pre-check for cluster services setup was unsuccessful on all the nodes.
Failures were encountered during execution of CVU verification request "stage -pre crsinst".
Verifying Physical Memory ...FAILED
rac2: PRVF-7530 : Sufficient physical memory is not available on node "rac2"
[Required physical memory = 8GB (8388608.0KB)]
rac1: PRVF-7530 : Sufficient physical memory is not available on node "rac1"
[Required physical memory = 8GB (8388608.0KB)]
Verifying Swap Size ...FAILED
rac2: PRVF-7573 : Sufficient swap size is not available on node "rac2"
[Required = 5.3685GB (5629256.0KB) ; Found = 3.875GB (4063228.0KB)]
rac1: PRVF-7573 : Sufficient swap size is not available on node "rac1"
[Required = 5.3685GB (5629244.0KB) ; Found = 3.875GB (4063228.0KB)]
Verifying resolv.conf Integrity ...FAILED
rac2: PRVG-2048 : no response for name "rac2" from the DNS server
"192.168.29.1" specified in "resolv.conf"
PRVG-10048 : Name "rac2" was not resolved to an address of the specified
type by name servers "192.168.29.1".
rac2: PRVG-2048 : no response for name "rac2" from the DNS server
"2405:201:e005:2105::c0a8:1d01" specified in "resolv.conf"
PRVG-10048 : Name "rac2" was not resolved to an address of the specified
type by name servers "2405:201:e005:2105::c0a8:1d01".
rac1: PRVG-2048 : no response for name "rac1" from the DNS server
"192.168.29.1" specified in "resolv.conf"
PRVG-10048 : Name "rac1" was not resolved to an address of the specified
type by name servers "192.168.29.1".
rac1: PRVG-2048 : no response for name "rac1" from the DNS server
"2405:201:e005:2105::c0a8:1d01" specified in "resolv.conf"
PRVG-10048 : Name "rac1" was not resolved to an address of the specified
type by name servers "2405:201:e005:2105::c0a8:1d01".
CVU operation performed: stage -pre crsinst
Date: 27 Sep, 2024 7:21:15 PM
CVU home: /u01/app/grid/19.0.0/gridhome_1/
User: grid
[grid@rac1 gridhome_1]$
start runInstaller and follow steps as shown screenshot.